D&b audiotechnik M2 Bedienungsanleitung Seite 18

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 24
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 17
18 d&b Stage monitors
Operation with D6 and D12
MAX12 MAX M6 M4
Max. LS per
channel
2 2 2 2
Max. LS per
channel in special
applications
1
3 3 3 3
Maximum loudspeakers per D6 or D12 channel
2-Way Active operation with D12
MAX12 MAX M6 M4 M2
Max. LS per D12
2 2 2 2 2
Maximum loudspeakers per D12
D6 and D12 controller settings
MAX12 MAX M6 M4 M2
CUT
x x x x x
HFA
x x x x
CPL
x x x x x
D6 and D12 controller settings for each loudspeaker
Passive and 2-Way Active operation
The D6 and D12 amplifiers can drive the MAX12, MAX, M6
und M4 passively, the D12 also allows 2-Way Active operation.
The M2 can only be driven in 2-Way Active operation.
CUT mode
Set to CUT, the cabinet low frequency level is reduced and is
configured for use with d&b active subwoofers.
The operation with D6 and D12 amplifiers
1
In applications with low continuous levels and low ambient temperatures
HFA mode
In HFA mode (High Frequency Attenuation), the HF response of
the system is rolled off. The HFA provides a natural, balanced
frequency response when a unit is placed close to listeners in near
field or delay use. High Frequency Attenuation begins gradually
at 1 kHz, dropping by approximately 3 dB at 10 kHz. This roll
off mimics the decline in frequency response experienced when
listening to a system from a distance in a typically reverberant
room or auditorium.
CPL function
The CPL (Coupling) function compensates for coupling effects
between closely coupled cabinets by reducing the low and mid
frequency level. CPL begins gradually at 1 kHz, with maximum
attenuation below 400 Hz (for M2 250 Hz), providing a balanced
frequency response when monitors are used in pairs. The CPL
function can be set in dB attenuation values between –9 and 0,
or a positive CPL value which creates an adjustable low frequency
boost around 65 Hz (0 to +5 dB).
MAX12 and MAX with other amplifiers
MAX12 and MAX may be driven by any high quality power
amplifier provided the output power does not exceed 500 Watts
into 8 ohms and an additional subsonic filter (25 Hz and 12
dB/octave) is used.
d&b SenseDrive
The D12 incorporates d&b SenseDrive for accurate control of
LF drivers in d&b loudspeakers driven 2-Way Active or in d&b
subwoofers driven actively, resulting in an extremely precise bass
performance, even at high levels. SenseDrive is only available
using a D12 fitted with EP5 connectors and appropriate 5-wire
cabling. For further information please refer to the d&b TI 340
SenseDrive, which is available for download at www.dbaudio.com.